HOW TO:

Use Link Monitor Mode

Link Monitor Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use it:

  • Press and hold the right-arrow button for 5 seconds. The display should show a number in each window. These numbers are actually the address being called upon by the central. The left number represents the group number, while the right number represents the satellite number. As the central calls different satellites, these numbers will change automatically.
  • If two different satellites on the same communication wire path are put into Link Monitor Mode at the same time, the numbers showing should always be the same between the two satellites. If only one shows the numbers changing, then there is a problem with the communication system in or near the satellite that has the display that does not change.
  • To end Link Monitor Mode, press the STOP button.

ALL OTHER TORO® NETWORK LTC® PLUS TOPICS:

HOW TO: Reinitialize a Timing Mechanism

Turn off power. Then, press and hold the down-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test at...

HOW TO: Self-test a Timing Mechanism

Turn off power. Then, press and hold the up-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test at...

HOW TO: Use Calibration Mode

Calibration Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use Calibration Mode on any Network LTC® Plus satellite: Power down the cabinet...

ISSUE: A single station is not turning on or is stuck on

If a single station in your Network LTC® Plus system is not turning on or is stuck on, begin troubleshooting the problem by checking the condition of a couple key connection points...

ISSUE: Communication problems or no modem pulse/lights

If you are experiencing communication problems with your Network LTC® Plus satellite, and/or the Standard Modem is not lighting up, follow these steps to troubleshoot the issue...

ISSUE: Pump is not turning on

Test the functionality of the Pump Common by replacing it with a known operational Pump Common. If the issue still exists, the problem lies with the Power Distribution Board, and it should be repaired or replaced with a new one...

ISSUE: Timing Mechanism buttons are not working

If the buttons on the Timing Mechanism in your Toro Network LTC Plus cabinet are not working, the issue is likely the result of a malfunctioning keypad or malfunctioning buttons on the printed...

ISSUE: Timing Mechanism is dead

If the Timing Mechanism in your Toro Network LTC® Plus cabinet appears dead, or is not receiving any power, you first need to check the two LEDs on the Power Distribution Board. You will troubleshoot differently depending...

ISSUE: Timing Mechanism reporting the wrong number of stations

Test the functionality of the Timing Mechanism by replacing it with a known operational Timing Mechanism. If the issue still exists, the problem lies with the Power Distribution Board, and...