ISSUE:

A single station is not turning on or is stuck on

If a single station in your Network LTC® Plus system is not turning on or is stuck on, begin troubleshooting the problem by checking the condition of a couple key connection points:

  • Check for debris or corrosion in the connection between the Power Distribution Board and the corresponding 8-Station Output Board, as well as the output contacts and wiring at the black output connecter. If there is corrosion, the 8-Station Output Board is likely faulty and should be repaired or replaced.
  • Verify that there is a good connection (free of corrosion and debris) between the 8-station Output Board and the 16-Station Switch & Surge Board.
  • If everything checks out, the problem may be related to the Timing Mechanism or Power Distribution Board. Check this by swapping these components with known operational units from another satellite.

ALL OTHER TORO® NETWORK LTC® PLUS TOPICS:

HOW TO: Reinitialize a Timing Mechanism

Turn off power. Then, press and hold the down-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test at...

HOW TO: Self-test a Timing Mechanism

Turn off power. Then, press and hold the up-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test at...

HOW TO: Use Calibration Mode

Calibration Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use Calibration Mode on any Network LTC® Plus satellite: Power down the cabinet...

HOW TO: Use Link Monitor Mode

Link Monitor Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use it: Press and hold the right-arrow button for 5 seconds. The display should show a...

ISSUE: Communication problems or no modem pulse/lights

If you are experiencing communication problems with your Network LTC® Plus satellite, and/or the Standard Modem is not lighting up, follow these steps to troubleshoot the issue...

ISSUE: Pump is not turning on

Test the functionality of the Pump Common by replacing it with a known operational Pump Common. If the issue still exists, the problem lies with the Power Distribution Board, and it should be repaired or replaced with a new one...

ISSUE: Timing Mechanism buttons are not working

If the buttons on the Timing Mechanism in your Toro Network LTC Plus cabinet are not working, the issue is likely the result of a malfunctioning keypad or malfunctioning buttons on the printed...

ISSUE: Timing Mechanism is dead

If the Timing Mechanism in your Toro Network LTC® Plus cabinet appears dead, or is not receiving any power, you first need to check the two LEDs on the Power Distribution Board. You will troubleshoot differently depending...

ISSUE: Timing Mechanism reporting the wrong number of stations

Test the functionality of the Timing Mechanism by replacing it with a known operational Timing Mechanism. If the issue still exists, the problem lies with the Power Distribution Board, and...