ISSUE:

A single station is not turning on or is stuck on

If a single station in your Network LTC® version 2 system is not turning on or is stuck on, begin troubleshooting the problem by checking the condition of a couple key connection points:

  • Check for debris or corrosion in the connection between the Power Distribution Board and the corresponding 4-Station Output Board, as well as the output contacts and wiring at the black output connecter. If there is corrosion, the 4-Station Output Board is likely faulty and should be repaired or replaced.
  • Check to see if the 4-Station Output Board switches can easily be changed and work in all three positions (On, Off, and Auto). If there are issues here, the 4-Station Output Board should be repaired or replaced.
  • If the 4-Station Output Board checks out, the problem may be related to the Timing Mechanism or Power Distribution Board. Check this by swapping these components, with known operational units from another satellite.

ALL OTHER TORO® NETWORK LTC® V2 TOPICS:

HOW TO: Reinitialize a Timing Mechanism

Turn off power. Then, press and hold the down-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test...

HOW TO: Self-test a Timing Mechanism

Turn off power. Then, press and hold the up-arrow button while powering the satellite back up. Continue holding the button until the second series of rapid beeps is heard. The Timing Mechanism will go through a self-test...

HOW TO: Use Calibration Mode

Calibration Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use Calibration Mode on any Network LTC® version 2 satellite: Power down the cabinet...

HOW TO: Use Link Monitor Mode

Link Monitor Mode is used for testing/troubleshooting/pinpointing issues within the communication system. Follow the steps below to use it: Press and hold the right-arrow button for 5 seconds. The display should show...

ISSUE: Communication problems or no modem pulse/lights

If you are experiencing communication problems with your Network LTC® version 2 satellite, and/or the Standard Modem is not lighting up, follow these steps to troubleshoot the issue...

ISSUE: Pump is not turning on

Test the functionality of the Pump Common by replacing it with a known operational Pump Common. If the issue still exists, the problem lies with the Power Distribution Board, and it should be repaired or replaced with a new one.

ISSUE: Timing Mechanism buttons are not working

If the buttons on the Timing Mechanism in your Toro Network LTC version 2 cabinet are not working, the issue is likely the result of a malfunctioning keypad or malfunctioning buttons...

ISSUE: Timing Mechanism is dead

If the Timing Mechanism in your Network LTC® version 2 cabinet appears dead, or is not receiving any power, troubleshoot the issue by checking the power going into the Timing Mechanism from the Power Distribution Board...

ISSUE: Timing Mechanism reporting wrong number of stations

Test the functionality of the Timing Mechanism by replacing it with a known operational Timing Mechanism. If the issue still exists, the problem lies with the Power Distribution Board...