Topics include troubleshooting, how-to's, and more!
Begin troubleshooting this issue by reinitializing the Timing Mechanism:
ALL OTHER RAIN BIRD® PAR 16/24 & MSC 16/24 TOPICS:
ISSUE: Stations are not turning on or are stuck on
Ensure that the pins are straight and free of corrosion at the top connectors where the Timing Mechanism plugs in. Check for loose or corroded field wires at the screw-in connectors. If there are...
ISSUE: Timing Mechanism is dead
Using a multi-meter, measure the power going out of the Power Transformer to the Timing Mechanism. The blue wire (between pins 2 and 3) should read approximately 8.5V AC. The orange wire (between pins 1 and 4) should read...
ISSUE: Timing Mechanism is displaying "RAM Memory Error"
This error message indicates an internal failure. The Timing Mechanism should be repaired or replaced with a new one.
ISSUE: Timing Mechanism is stuck in startup loop
Begin troubleshooting this issue by reinitializing the Timing Mechanism: Disconnect the power connector. With the power off, hold down the buttons: "WEEKDAY/CYCLE"...